| Description |
2.5KVA |
3KVA |
3.5KVA |
4KVA |
5KVA |
6KVA |
7.5KVA |
10KVA |
12KVA |
| |
Back-up Mode |
| Output Wave Form |
Pure Sine Wave |
| Nominal Battery Voltage |
48V DC |
48V DC |
48V DC |
48V DC |
96V DC |
120V DC |
120V DC |
180V DC |
192V DC |
| 120V DC |
180V DC |
180V DC |
360V DC |
|
| 180V DC |
|
|
|
|
| Output Power Factor |
0.8 |
| No Load O/P Voltage |
220V ± 5V AC |
230V ± 5V AC |
| O/P Frequency |
50Hz ± 1 Hz |
| Max. No Load Batt. Current |
1.1A ± 0.2A |
| Full Load O/P Current |
8.7A±0.5A |
10.5A±
0.5A |
11.5A±
0.5A |
13A±
0.5A |
17A±
0.5A |
21A±
0.5A |
27A±
0.5A |
34A±
0.5A |
42A±
0.5A |
| Total Harmonic Distortion |
< 3% |
| Low Battery Indication |
10.5V +/- 0.2V DC Per Battery (12V DC Each) |
| Low Batt. Cut OFF |
10.3V +/- 0.2V DC Per Battery (12V DC Each) |
| |
Mains Mode |
| Max. Charging Current |
10A ± 1A |
| Full Load O/P Current at Mains Mode |
15A±1A |
17A±1A |
17.6A±1A |
19.5A±1A |
25A±1A |
30A±1A |
35A±1A |
42A±1A |
45A±1A |
| Boost Charging Voltage |
14.2V +/- 0.2V DC Per Battery (12V DC Each) |
| Float Charging Voltage |
13.7V +/- 0.2V DC Per Battery (12V DC Each) |
| |
Normal Mode |
| Input Voltage Range |
100V to 280V AC ± 10V AC |
125V to 280V AC ± 10 AC |
| Change Over Time (mains to Inverter) |
< 40 ms |
| Change Over Time (Inv. to mains) |
< 25 ms |
| |
UPS Mode |
| Input Voltage Range |
180V to 260V AC ± 5V AC |
| Change Over Time (mains to Inverter) |
< 10 ms |
| Change Over Time (Inv. to mains) |
< 10 ms |
| |
Protections |
| Protections |
Output Not Ok Battery Voltage Low (4 Auto Retries), Over Load (6 Auto Retries) |
| Battery Over Charge, Over Temperature, Short Circuit, Mains MCB Tripped |
| |
Displays |
| Displays |
Welcome Message, Capacity, Output Voltage, Output Frequency, Load Percentage |
| Input Voltage and Frequency, Load Percentage, Battery Charging, Battery Voltage and All Protections |
| |
Environmental Parameters |
| Operating Temperature |
0 - 45 Deg. |
| Acoustic Noise at 1Mtr. |
< 45 db |
| Relative Humidity |
Max 95%, Non-condensing |
| Tharmal Management |
Integrated Cooling (Fan & Heat Sink) |
| |
Weight and Dimensions |
| With Packaging L×W×H in mm |
470×440
×610 |
470×440 ×610 |
470×440 ×610 |
470×440
×610 |
500×495 ×660 |
500×495
×660 |
600×500
×740 |
600×500
×740 |
600×500
×740 |
| Without Packaging L×W×H in mm |
310×290 ×450 |
310×290
×450 |
310×290
×450 |
310×290
×450 |
350×300 ×540 |
350×300
×540 |
550×350 ×660 |
550×350
×660 |
550×350
×660 |
| Net Weight |
29 Kg |
32 Kg |
32 Kg |
45 Kg |
54 Kg |
54 Kg |
78 Kg |
89 Kg |
104 Kg |
| Gross Weight |
36 Kg |
39 Kg |
39 Kg |
49 Kg |
58 Kg |
58 Kg |
89 Kg |
100 Kg |
115 Kg |
| Load Chart |
| Application |
Load |
3KVA |
5KVA |
7.5KVA |
10KVA |
12KVA |
| Petroleum Outlet |
Fan |
1 |
4 |
5 |
5 |
5 |
| Tube light |
2 |
4 |
5 |
8 |
8 |
| Petrol Filing Machine |
1 |
2 |
3 |
4 |
5 |
| Institute |
Fan only |
30 |
50 |
75 |
100 |
110 |
| Fan |
18 |
35 |
55 |
70 |
75 |
| Tube light |
15 |
20 |
35 |
40 |
50 |
| Browsing Centre |
A.C |
- |
1 |
1 |
2 |
2 |
| |
Fan |
5 |
4 |
8 |
8 |
10 |
| |
Tube light |
5 |
4 |
8 |
8 |
10 |
| |
Computer |
5 |
2 |
6 |
6 |
6 |
| Browsing Centre |
Fan |
5 |
10 |
12 |
20 |
25 |
| |
Tube light |
5 |
10 |
12 |
20 |
25 |
| |
Computer |
5 |
8 |
12 |
15 |
20 |
| Corporate Bldg. |
A.C |
- |
1 |
1 |
2 |
2 |
| |
Fan |
18 |
8 |
12 |
16 |
20 |
| |
Tube light |
15 |
8 |
12 |
16 |
20 |